Vista de página 76
EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com
E11011 1.77
II 2 (1) G Ex ia IIC T4 Zone 0
The lightning protection SBGX 01 is placed
between the sensor and the amplifier.
Lightning overvoltage is discharged to earth.
Design SBGX 01
Dimensions
ID-No. Z01007
Type SBGX 01
Ex marking II 2 (1) G Ex ia IIC T4
Certificate No. TÜV 03 ATEX 2073
Ambient temperature [°C] 20...+120
for T-classes T4 : 120
Maximum values Ui = 45 V
Ii = 3.3 A
Pi = 1.3 W
Ci = negligibly small
Li = negligibly small
Housing material sIuminium
Protection [EN 60529] IP 67
Connection terminal space
Flow Sensors
- Lightning protection
2
1
3
4
5
6
7
8
BK
BU
WH
BN
BN
WH
BU
BK
SBGX 01
Verstärker
Amplifier
Sensor
125
80
15
42
PG 9
PG 13,5
Vista de página 76